GAS PURIFICATION & CONTROL PANEL FOR AAS
GAS PURIFICATION & CONTROL PANEL FOR AAS

GAS PURIFICATION & CONTROL PANEL FOR AAS

MOQ : 1 Unit

GAS PURIFICATION & CONTROL PANEL FOR AAS Specification

  • Accuracy
  • Flowmeter accuracy 2%
  • Control Type
  • Manual Toggle Valves and Pressure Gauge
  • Features
  • Triple-stage gas purification; easy wall-mountable design; pressure regulation; inlet and outlet test points; leak proof assembly
  • Display Type
  • Analog (flowmeter and pressure gauge)
  • Glass Type
  • Borosilicate (for flow meters)
  • Shape
  • Rectangular panel
  • Temperature Resistance
  • -20C to +50C
  • Type
  • Gas Purification & Control Panel for AAS
  • Dimension (L*W*H)
  • 450mm x 300mm x 100mm (approx)
  • Equipment Type
  • Gas Purification and Distribution/Regulation Panel
  • Equipment Materials
  • Stainless steel, brass, high quality engineering plastics
  • Power
  • Not required (no electrical parts)
  • Material
  • Stainless steel panel with glass flow meters, brass control valves, chemically resistant tubing
  • Application
  • Atomic Absorption Spectrophotometer Gas Line Purification and Control
  • No. of Gas Purification Stages
  • 3 (Moisture trap, Hydrocarbon trap, Particulate trap)
  • Pressure Gauge Range
  • 0-7 kg/cm2
  • Flowmeter Range
  • 0-5 LPM
  • Maximum Inlet Pressure
  • 10 kg/cm2
  • Connections
  • 1/4" Swagelok compression fittings
  • Maximum Outlet Pressure
  • 6 kg/cm2
  • Panel Mounting
  • Wall-mounted/Bench-top
  • Purification Type
  • Moisture, Oil, Hydrocarbon and Dust removal
  • Suitable Gases
  • Nitrous Oxide, Acetylene, Air (for AAS)
 

GAS PURIFICATION & CONTROL PANEL FOR AAS Trade Information

  • Minimum Order Quantity
  • 1 Unit
  • Supply Ability
  • 10 Units Per Month
  • Delivery Time
  • 7 Days
 

About GAS PURIFICATION & CONTROL PANEL FOR AAS



The GAS PURIFICATION & CONTROL PANEL FOR AAS is a first-string solution, pivotal for laboratories seeking streamlined gas management for Atomic Absorption Spectrophotometers. This trending, in-demand unit offers preeminent triple-stage purification, removing moisture, oil, hydrocarbons, and dust. Designed for versatility, its wall-mounted or bench-top setup features premium stainless steel, brass, and borosilicate glass for durability. Key highlights include leak-proof assembly, manual toggle valves, and precise, analog gauges. Compatible with nitrous oxide, acetylene, and air, this panel ensures top-tier gas delivery without requiring power-making it an industry-leading offer for service providers and manufacturers in India.

Versatile Solution for Pure Gas Supply Needs

The GAS PURIFICATION & CONTROL PANEL FOR AAS is purpose-built for Atomic Absorption Spectrophotometer gas lines, ensuring both specialized and general laboratory gas needs are met. With three dedicated purification stages, it efficiently removes moisture, oil, hydrocarbons, and dust. The ergonomic, wall-mountable design supports flexible usage, while its stainless steel and chemically resistant construction promises longevity. Ideal for manual, analog-controlled environments, it delivers accurate, stable gas flow for critical scientific processes and daily laboratory operations.


Seamless Delivery and Trusted Certifications

Our GAS PURIFICATION & CONTROL PANEL FOR AAS comes with convenient payment terms and is available for quick delivery nationwide. We offer competitive pricing for bulk and export orders, targeting the main domestic market across India. Each unit is crafted under rigorous quality standards, with relevant certifications ensuring reliability and compliance. Whether you require a single piece or large-scale supply, we guarantee consistent performance, backed by dependable after-sales support and transparent transaction processes.


FAQ's of GAS PURIFICATION & CONTROL PANEL FOR AAS:


Q: How does the three-stage purification system work in this panel?

A: The three-stage system sequentially filters out moisture, hydrocarbons, and particulates from the gas, ensuring maximum purity for safe and efficient Atomic Absorption Spectrophotometry operations.

Q: What gases can be used with the GAS PURIFICATION & CONTROL PANEL FOR AAS?

A: This panel is compatible with nitrous oxide, acetylene, and air, commonly used in AAS applications.

Q: Where can this control panel be mounted?

A: The GAS PURIFICATION & CONTROL PANEL FOR AAS offers flexible installation and can be easily mounted on a wall or placed on a bench-top according to your laboratory's requirements.

Q: What are the primary benefits of using this purification panel?

A: Key benefits include superior gas purity, trouble-free pressure regulation, enhanced safety, and improved analytical accuracy, all delivered in a compact and durable assembly.

Q: What is the process for installing and operating the panel?

A: Installation is simple-just connect the 1/4" Swagelok fittings to the gas lines, ensure a secure leak-proof setup, and use the manual toggle valves and analog gauges for regulation and monitoring.

Q: When should the purification traps be replaced or maintained?

A: Regular maintenance is recommended based on gas usage and contamination levels; visual indicators or reduced performance signal the need for trap replacement or servicing.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

More Products in GAS PURIFICATION & CONTROL PANEL FOR GC Category

Gas Distribution Panel

Gas Distribution Panel

Minimum Order Quantity : 1 Piece

Material : Stainless Steel

Type : Other, Wall Mounted Gas Distribution Panel

Equipment Materials : Stainless Steel (SS 304)

Temperature Resistance : Upto 80C

Shape : Rectangular

Cylinder Regulators

Cylinder Regulators

Minimum Order Quantity : 1 Unit

Material : Brass, Stainless Steel

Type : Other, Cylinder Regulator

Equipment Materials : High quality Brass Body with Chrome plated finish

Temperature Resistance : Suitable for standard room temperature applications

Shape : Cylindrical body with attached gauges

Gas Change Over

Gas Change Over

Minimum Order Quantity : 1 Unit

Material : Stainless Steel / Mild Steel

Type : Other, Automatic Gas Change Over

Equipment Materials : Mild Steel

Temperature Resistance : 20C to 60C

Shape : Rectangular

Moisture Trap - Oxy Trap

Moisture Trap - Oxy Trap

Minimum Order Quantity : 1 Unit

Material : Borosilicate Glass

Type : Other, Moisture Trap

Equipment Materials : Borosilicate Glass Body, PTFE Stopcock

Temperature Resistance : Up to 250C

Shape : Cylindrical



Back to top